A PCB press-fit connection must match the terminal's press-in zone to the plated through-hole. IEC 60352-5:2020 provides a framework for mechanical, electrical and environmental testing of solderless press-in connections. The terminal and PCB supplier data still need to match the actual board thickness, hole size and insertion tooling. A part number alone does not prove the assembled joint.

Press-fit terminal validation inputs

First match the terminal compliant zone to the finished plated through-hole, tolerances and board thickness. Record board support, insertion speed and the force-displacement curve, then remeasure contact resistance under the project plan. Use the approved limits for the selected terminal and board.

View the hole diagram and blank validation record →

DRAWING & SELECTION

Match the terminal and hole before validating insertion

Review the compliant zone, finished hole, copper wall and board thickness on controlled drawings. The diagram explains the fit; its curve is qualitative. The selected terminal system and approved test plan must define the acceptance window.

Press-fit: plated-hole contact and insertion traceCross-section separates PCB substrate, plated copper wall and compliant terminal, with board support below. The qualitative force trace has no numeric acceptance window.Press-fit: plated-hole contact and insertion traceA · Plated through-hole sectionInsertionCopper wallPCB substrateCompliant contactSupport near holeValidate hole, plating and terminal togetherB · Illustrative insertion traceForce FDisplacement sNo acceptance window or measured dataLink each trace to sample and hole
Selection schematic, not to scale. Geometry, curves and force direction explain review inputs; they are not measured results, universal ratings or acceptance limits.
Press-fit observations and verification checks
ObservationCheck firstRecord and verify
High insertion force or an abrupt riseFinished hole, compliant-zone dimensions, alignment and board supportLink measured hole data, the force-displacement file and specimen ID; follow the approved abnormal-process procedure
Low retentionPin/hole fit, hole wall and previous insertionsUse separate specimens for extraction; do not release an extracted joint as a qualified assembly
Expected force curve but abnormal resistanceMeasurement wiring, test current, temperature and interfaceRetain initial and post-exposure readings with the same measurement points
Board bow or damage around the holeSupport, insertion depth, stack-up and surrounding structureRecord visual and required section inspection; a peak force alone cannot establish an undamaged joint

This guide addresses solderless press-in connections. Solder terminals and press-fit terminals require separate structural and validation reviews; they are not interchangeable by default.

A reusable validation record

Record drawing revisions, finished hole and copper wall, board thickness, tooling and calibration, insertion speed, curve files, contact resistance and acceptance references. Enter actual measurements; the blank template is not a certificate.

Download blank press-fit validation CSV ↓
01

Treat the terminal and plated hole as one system

An elastic press-in zone deforms within its design range during insertion and then maintains contact normal force. TE Connectivity describes compliant pins as working with the plated hole as a press-fit system. A change to hole size, copper plating, board thickness or terminal geometry can move the assembly outside its previously verified range.

The drawing review should lock the terminal and press-in zone, finished hole diameter and tolerance, copper plating, board material and thickness, insertion direction, edge distance, board support and press-head alignment. Use limits supplied for that terminal and board system.

02

Force-displacement records reveal more than a peak value

The 2020 revision of IEC 60352-5 refers to recording insertion and extraction force curves. Keep force versus displacement, insertion speed, tooling and support location, board revision and measured hole data with each test. A maximum force alone hides how the terminal enters the hole, develops contact and reaches its seated position.

Acceptance limits should come from the terminal specification and an approved application evaluation. Confirm the window with first articles and representative tolerance samples, then check that production equipment reproduces it. Do not transfer a curve from a different terminal or board thickness.

03

Tie mechanical and electrical results to the same specimens

Record contact resistance, terminal condition, board distortion and damage around the hole before and after insertion. Higher-reliability programs may add electrical retest and cross-section inspection after the specified temperature or corrosion exposure. IEC defines test methods for comparison; the product owner sets the application acceptance criteria.

Rework or a second insertion changes the terminal and hole interface. Manufacturing instructions should separately define removal, reuse and post-repair inspection rules.

  • State finished-hole diameter, plating, board material, thickness and tolerance source
  • Retain insertion and extraction curves with tooling calibration records
  • Link resistance, damage and environmental results to specimen IDs
04

Include the press-fit system in the RFQ package

Submit the terminal drawing, PCB hole table, stack-up, target current and expected environment together. If the joint carries structural load or must be removed, state the load direction and service count. The supplier can then confirm the matching range and the application owner can approve a validation plan.

Apply this guide to a project

Use product pages to identify the hardware family and the calculator for early estimates only. Acceptance depends on drawings, operating conditions and project tests.

Sources

  1. IEC 60352-5:2020 press-in connection requirements and tests↗
  2. TE Connectivity press-fit technology and compliant pins↗
  3. TE Connectivity connector press-machine force monitoring↗