Report loading method, PCB support and failure location alongside peak shear force. Peak force cannot distinguish solder fracture, pad separation or laminate damage, and cannot directly establish tightening torque. Match the test to assembly risk before choosing specimens and criteria.

01

Define the mechanical objective

We reviewed IEC 60068-2-21 (2021 edition)'s public scope for termination and mounting robustness during assembly/handling, including SMDs. It replaces older editions and IEC 60068-2-77. Confirm suitable methods for actual hardware; citing the number alone does not qualify every geometry under one load.

We recommend identifying process comparison, assembly-load assessment or failure analysis as the objective. Retain PCB/land designs and reflow/rework state. Shear results remain separate from equipment vibration, shock and maintenance evaluation.

02

Make loading and support reproducible

Record tool contact, direction, speed and underside support with drawings or photographs. Tall standoffs and low busbars require different access reviews. Prevent unintended restraint or tool contact with the PCB before the intended load.

Nordson's solder-bump discussion demonstrates test-speed sensitivity of failure modes. This is method context, not acceptance parameters for heavy hardware. Ask the appropriate laboratory to establish tool geometry, measurement range and method for the actual parts.

03

Read curves with failure photographs

We recommend retaining curves, peaks and photographs, separating solder fracture, interface separation, pad lift and laminate damage. Identify the basis for mixed-failure classification. Similar averages still need review of locations and scatter.

Agree sample count, exceptions and criteria before testing. Do not keep only the highest specimen or derive universal screw torque or harness limits from a peak. Segregate destructive specimens. Electrical continuity of an intact sample does not complete mechanical validation.

04

Frequently asked questions

Does a high peak prove sound pads? Inspect failure locations and laminate condition separately.

Can solder-ball settings be copied to standoffs? Reassess geometry, fixtures and method applicability.

05

Acceptance and RFQ inputs

Provide hardware/PCB drawings, lands and load application points. Agree specimen state, support, contact and curve delivery with failure classification and exception disposition. List tightening and harness-load objectives separately.

Apply this guide to a project

Use product pages to identify the hardware family and the calculator for early estimates only. Acceptance depends on drawings, operating conditions and project tests.

Sources

  1. IEC 60068-2-21 scope↗
  2. Nordson shear-speed context↗