Wetting-balance curves support comparison under consistent conditions, not one universal acceptance number for every copper part. Identify paste, bath or globule methods, agree project criteria and confirm soldering on the actual PCB.

01

Identify the measurement method

IEC 60068-2-83, 2025 edition, describes solder-paste wetting balance for comparative assessment of metallic or metallized SMD terminations. IEC 60068-2-69, 2017 edition with its 2019 amendment, covers bath and globule methods. Similar-looking curves do not make different media equivalent.

Record the method, revision, finish and measured location. A generic solderability pass does not identify whether evidence corresponds to the current SMT process. Distinguish a termination measurement from complete-part assembly qualification.

02

Compare curves on a consistent basis

Both IEC public scopes state that their data are not intended as absolute quantitative pass-fail data. Where acceptance criteria are needed, have the test and assembly owners establish an applicable project basis. Equipment defaults are not universal component specifications.

Retain raw curves, specimen geometry, pretreatment, medium designation and equipment conditions. Review changes in finish, storage or sampling position before combining results. Do not attribute every difference solely to copper quality.

03

Qualify the real pad and assembly

Propose trials with the actual copper hardware, paste and PCB, recording relevant thermal histories and agreed joint inspections. Comparative wetting helps screen surface conditions; pad layout, printing and reflow still require confirmation.

If curves and production observations disagree, retain same-batch samples and complete process records. Check medium and sampling representativeness first. Do not merely move the acceptance line or extend contact time to erase a report difference.

04

Frequently asked questions

Does a good bath curve guarantee paste-reflow acceptance? The actual process still needs qualification.

Can all component sizes share one force limit? Match geometry, method and project criteria first.

05

UPS SMT copper-hardware RFQ inputs

Supply component and pad drawings, finish, paste designation and reflow route. Identify material screening versus batch acceptance. Quote raw curves, condition records and actual-board validation separately for hardware and assembly review.

Apply this guide to a project

Use product pages to identify the hardware family and the calculator for early estimates only. Acceptance depends on drawings, operating conditions and project tests.

Sources

  1. IEC 60068-2-83 solder-paste wetting balance scope↗
  2. IEC 60068-2-69 consolidated solder bath and globule wetting balance scope↗
  3. Related industry and selection guidance↗
  4. Submit a drawing and project RFQ↗