In double-pulse testing, fixture-busbar geometry and probe reference become part of the measurement loop. The goal is an explainable, repeatable test condition, not simply a prototype that can carry current.

01

Fix the commutation loop between the module and DC link

Map the DC-link capacitor, power module, load inductor, positive and negative busbars, gate drive and measurement reference. Confirm layer order, end overlap and module mounting plane before reviewing loop area, parasitics and probe-ground arrangement.

02

Build measurement repeatability into the mechanics

Busbar hole pattern, module datum, fastener load and probe support affect the loop after repeat assembly. Keep defined measurement faces and insulating separation instead of correcting position by hand-bending a link after each module change.

  • Record four-wire drop and rise in unloaded and loaded conditions
  • Check withstand, creepage, burr direction and safe clearance around probes
  • Repeat waveform, position and fastener checks after module changes and specified clamping cycles
03

State waveform and fixture boundaries in the RFQ

Include module package, DC-link location, test voltage and current, pulse width, switching frequency, busbar layers, insulation, mounting torque, probe type, fixture envelope and sample quantity. Acceptance should bind one load, probe, calibration and safety procedure.