Identify DC-input, local bus and motor-phase copper parts separately, with the current definition and duration at each location. A single maximum-current number does not distinguish average, RMS, an instantaneous peak or a protection threshold, and cannot specify every connection.

01

Mark the hardware position on the circuit

Number supply-input connections, links near DC capacitors and motor-phase terminals separately. TI's phase-current brief distinguishes direct in-line measurement from other sensing locations requiring circuit-dependent processing. Location is part of the meaning of the current data.

Associate each record with a part identity. Do not transfer input-side data to a phase terminal without analysis, or treat a semiconductor current figure as the permissible current of a copper block and its solder joint.

02

Supply waveform, statistic and time window together

Separate continuous and short-time operation. Define average or RMS and its calculation window for continuous conditions. Give peak amplitude, duration and repetition conditions separately. Provide startup, stall or regenerative operation according to the actual control strategy.

State PWM conditions and measurement bandwidth. TI describes rapid common-mode changes affecting phase-current sensing, so apparent spikes require measurement-disturbance review. Without topology, waveform and control conditions, do not use a fixed multiplier to convert DC current into phase current.

03

Add thermal and mechanical boundaries

Supply copper dimensions, solder structure, PCB copper, mating cable and cooling conditions before agreeing resistance and temperature-rise validation. RMS alone does not complete selection. Contact resistance, frequency-dependent loss and heat removal also matter.

Describe fastening, cable loads and support for terminal posts rather than leaving external loads to solder joints alone. Keep current location, temperature-sensor positions and assembly state in sample-test records.

04

Frequently asked questions

Is rated motor power enough to choose terminal size? Bus voltage, operating modes, current definitions and connection structure are also needed.

Is a protection threshold a continuous rating? It defines a protection action condition; continuous operation still needs waveform and thermal validation.

05

Motor-controller hardware RFQ inputs

Send annotated circuit or assembly drawings. List DC and phase conditions, waveform definitions, durations, solder process and cable restraint separately. Use the motor-controller application link to identify blocks and terminals, then submit review conditions through the drawing-RFQ link.

Apply this guide to a project

Use product pages to identify the hardware family and the calculator for early estimates only. Acceptance depends on drawings, operating conditions and project tests.

Sources

  1. TI SBOA160D in-line motor phase-current sensing↗
  2. Related application and hardware selection↗
  3. Send drawings and operating conditions for RFQ↗