Choose a spring at its installed working height. A point-contact resistance value cannot establish complete equipment shielding performance.
DRAWING & SELECTION
Choose a working point between contact loss and over-compression
Define free height, installed working height and mating-surface tolerances, then check the selected spring's force/travel data. The loose assembly must maintain contact; the tight assembly must remain within the permitted elastic working range.
| Review item | Required input | Specimen checks |
|---|---|---|
| Height and travel | Free/working height, mating surface, board bow and tolerance stack | Check minimum contact and maximum compression against the supplier's permitted travel |
| Contact force and surface | Force at the working point, material, finish and mating condition | Measure force and resistance at the installed position; record temperature and method |
| Reflow and service | Actual thermal process, removal direction, cycles and nearby parts | Recheck height, appearance and contact after the specified heat process and cycling |
| Shielding and environment | Seam, ground layout, frequency range and service conditions | Validate the contact and system shielding separately; point resistance cannot replace a system test |
A shield clip retains the can; a ground spring makes an elastic contact. Define their functions, assembly and test boundaries separately. A material name alone does not establish system shielding performance.
Keep assembly conditions and retest results together
Record free/working height, tolerance extremes, force, mating surface, reflow files, cycling/environmental conditions, initial/final resistance and acceptance references.
Download blank spring selection and validation CSV ↓Mechanical envelope
Check minimum contact and maximum compression across the tolerance stack, including lateral movement.
- Specify mating surface and service cycles.
- Inspect after the thermal process and cycling.
Contact and shielding
Review finish, contamination and motion. Measure contact condition and system shielding at their respective boundaries.
- Record installed position and load.
- Define environmental and electrical checks.
Assembly and service
Check removal tools and nearby components so service does not damage joints or clips.
- Trial packaging and pickup on the intended line.
- Provide working height, shield and pad geometry.
Apply this guide to a project
Use product pages to identify the hardware family and the calculator for early estimates only. Acceptance depends on drawings, operating conditions and project tests.