Induction-heating resonant loops carry high-frequency current through repeated thermal cycles, while SiC switches amplify layout parasitics. Copper hardware should be validated as one assembly across current path, cooling, insulation and manufacturing takt.
Set the lamination order from the resonant loop
Mark the SiC half bridge, resonant capacitors, coil output, return path and protection branches, then record frequency, continuous and peak current, ripple and short-circuit duration. Define positive and negative layers, end overlap, 3D jumpers and supports from the useful loop area.
Measure high-frequency loss separately from reflow quality
Busbar thickness, finish and nearby metal affect AC loss and rise. SMT structures also see heavy-copper heat capacity, paste volume, stencil zoning and underside support. After reflow, confirm end height and insulation barriers remain within the drawing.
- Measure resonant frequency, four-wire drop, rise, power loss and switch overshoot
- Check coplanarity, pad peel, withstand, creepage and coil keep-outs
- Repeat busbar, terminal and insulation checks after thermal, vibration and overload tests
Include coil interfaces and process takt in the RFQ
Provide the coil end, cooling method, power curve, frequency range, copper grade, finish, insulation, pads, bolt torque, reflow profile, inspection points, carrier direction and annual volume. Tie acceptance records to the actual load, fixture and temperature locations.
Apply this guide to a project
Use product pages to identify the hardware family and the calculator for early estimates only. Acceptance depends on drawings, operating conditions and project tests.