The objective is not simply a thinner conductor. Aerospace electric-propulsion interconnects require a testable boundary between mass, commutation-loop geometry, cooling, insulation and fault isolation. Any substitution belongs in the installed configuration and certification plan.

01

Fix the commutation loop and mass budget first

Place the DC-link capacitor, power module, phase outputs, shield and protective earth on the same layout. Record continuous and peak power states, switching frequency, allowed drop, cooling method and per-part mass budget before defining layer order and terminal spread.

02

Validate fault, environment and serviced conditions

Insulation films, end fasteners, supports and finishes should retain their specified state after temperature, vibration, humidity, low-pressure and maintenance exposure. Dissimilar-material or lightweight transitions also need defined cut edges, seals, contact faces and inspection methods.

  • Measure commutation-loop inductance, four-wire drop, rise and switching overshoot
  • Inspect insulation, end position, torque and grounding before and after environmental tests
  • Retain material lots, process records, measurement locations and assembly-configuration traceability
03

Supplier inputs must describe the installed configuration

Provide 2D and 3D data, materials and finishes, layer order, insulation system, mounting datums, cooling interface, fault-current boundary, fasteners, sampling plan and configuration-control requirements. This guide does not replace aircraft safety assessment or certification compliance evidence.

Apply this guide to a project

Use product pages to identify the hardware family and the calculator for early estimates only. Acceptance depends on drawings, operating conditions and project tests.

Sources

  1. EASA SC-VTOL-01 special condition for VTOL aircraft↗
  2. EASA Means of Compliance with SC-VTOL, Issue 2↗
  3. IEC 62477-1:2022 safety requirements for power electronic converter systems↗